Chapter 4. Usage
4.1 Turning On the Power Supply
(1) Checking Connections of the Emulator System
Before turning the power ON, check the connections of the PC4701, emulation pod, pod probe,
converter board and target system.
(2) Turning On the Power
Turn on the power of the emulator and target system as simultaneously as possible.
Turn off the power of the emulator and target system as simultaneously as possible.
Do not leave either the emulator or target system powered on, because of leakage current the
internal circuits may be damaged.
When turning on the power again after shutting off the power, wait about 10 seconds.
CAUTION
Notes on Power Supply:
•The emulator's pin VCC is connected to the target system in order to monitor target
system voltage. For this reason, the emulator cannot supply power to the target
system. Therefore, provide the target system with a separate power supply from that
of the emulator.
Keep target system power supply voltage within the MCU's specified range (2.7 to
5.5 V).
Do not change target system power supply voltage after power has been activated.