Figure 3.4 Removing pod probe M30220TF-PRB
(1) Unscrew the two screws of the M30220TF-PRB.
(2) Remove the M30220TF-PRB from the FLX64-PRB. In
this time, lift off the M30220TF-PRB horizontally.
Otherwise, the connector may cause a break.
CAUTION
When Connecting Pod Probe:
Be sure to turn off the power before making connections. Otherwise, the internal
circuits may be damaged.
The small connectors of the M30220TF-PRB (J3 and J4) are guaranteed for only 50
insertion/removal iterations.
The small connectors of the FLX64-PRB (J3 and J4) and M30220TF-PRB (J1 and
J2) are guaranteed for only 50 insertion/removal iterations.
3.3 Connecting the M30200T-RPD-E
The emulation pod for flash memory rewrite mode debug of the M30220 and M30221 Group MCUs
consists of the two products, the M30200T-RPD-E emulation pod main unit and the M30220TF-PRB
pod probe. Figures 3.3 and 3.4 show how to connect the M30220TF-PRB and how to remove it,
respectively.
Figure 3.3 Connecting pod probe M30220TF-PRB
(1) Connect the J1 and J2 connectors of the M30220TF-
PRB to the J3 and J4 connectors of the FLX64-PRB.
(2) Fix the FLX64-PRB by the two screws.