Renesas HS3802ECH62HE Información técnica

Busca en linea o descarga Información técnica para Redes Renesas HS3802ECH62HE. Renesas HS3802ECH62HE Technical information Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 29
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de pagina 0
1 2 3 4 5 6 ... 28 29

Indice de contenidos

Pagina 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Pagina 2

iPrefaceThank you for purchasing this user system interface cable (HS3802ECH62H) for the Renesas’soriginal microcomputer H8/3802, H8/38004 group.The H

Pagina 3

iiContentsSection 1 Configuration...1Section 2 Connection Proced

Pagina 4 - Cautions

1Section 1 ConfigurationCAUTIONUse an IC149-064-175-B51 socket (manufactured byYAMAICHI ELECTRONICS Co., Ltd.) for the FP-64Epackage IC socket on t

Pagina 5 - IMPORTANT INFORMATION

2Table 1 lists the HS3802ECH62H components. Please make sure you have all of thesecomponents when unpacking.Table 1 HS3802ECH62H ComponentsNo. Compon

Pagina 6 - DISCLAIMER

3Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator StationWARNINGObserve the precautions listed below. Failure

Pagina 7

4Emulator stationCable body connectorUser system interface cableE6000Figure 2 Connecting User System Interface Cable to Emulator Station

Pagina 8 - SAFETY PAGE

52.2 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Pagina 9

62.2.3 Inserting Cable HeadCAUTIONCheck the location of pin 1 before inserting.Align pin 1 on the IC socket for an FP-64E package on the user system w

Pagina 10

7Fasten the user system interface cable head to the IC socket for an FP-64E package on the usersystem with the four screws (M2 x 12 mm; with four flat

Pagina 11 - Contents

82.2.5 Fastening Cable BodyConnect the cable body to the cable head.Cable bodyCable headRemove jigPush the remove jigUser systemRemovingFigure 4 Fas

Pagina 12 - Section 1 Configuration

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Pagina 13

92.3 Recommended Dimensions for User System Mount PadFigure 5 shows the recommended dimensions for the mount pad (footprint) for the user systemwith a

Pagina 14

102.4 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 6. Unit: mmTo

Pagina 15 - User system interface cable

112.5 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Pagina 16

12Section 3 Installing the MCU to the User SystemCAUTION1. Check the location of pin 1 before inserting.2. Use a Philips-type screwdriver whose head

Pagina 17 - 2.2.4 Fastening Cable Head

13MCUPin 1IC socket (IC149-064-175-B51manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2 x 6 mm)with flat washersSocket coverFigure

Pagina 18

14Section 4 Verifying Operation1. When using the H8/3802 group E6000 emulator (HS3800EPI60H), turn on the emulatoraccording to the procedures descri

Pagina 19 - 2.2.5 Fastening Cable Body

15Figure 9 shows the system clock oscillator on the user system interface cable and the subclockinput specifications.R2 270R1 1 MHCU04HCU04To E6000 em

Pagina 20 - 10.10 max

16Section 5 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Pagina 21 - 25.016.7

H8/3802 Group FP-64E User System Interface Cable For E6000 Emulator User's ManualPublication Date: Rev.3.00, December 19, 2003Published by:

Pagina 22 - 18.6 21.5

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8/3802 Group FP-64EUser System Interface Cable for E6000 EmulatorREJ10B0099-030

Pagina 23

H8/3802 Group FP-64E User System Interface Cable for E6000 EmulatorUser’s ManualUser’s Manual Rev.3.0 2003.12H8/3802 HS3802ECH62HERenesas Microcomp

Pagina 24

CautionsKeep safety first in your circuit designs!1. Renesas Technology Corp. puts the maximum effort into making semiconductor productsbetter and mor

Pagina 25

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f

Pagina 26

IILIMITED WARRANTY Renesas warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Pagina 27 - Section 5 Notice

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Pagina 28

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Pagina 29 - User’s Manual

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or

Comentarios a estos manuales

Sin comentarios