29
Figure 2.4 [Performance Analysis] Dialog Box
(b) Measurement range
One of the following ranges can be specified. This depends on the item selected for [Mode] in
the [Performance Analysis] dialog box.
1. From the start to the end of the user program execution (When Normal Break is selected
for [Mode])
2. From the satisfaction of the condition set in Break Condition 1 to the satisfaction of the
condition set in Break Condition 2 (When Break condition 1->2 is selected for [Mode])
3. From the satisfaction of the condition set in Break Condition 2 to the satisfaction of the
condition set in Break Condition 1 (When Break condition 2->1 is selected for [Mode])
(In the second and third ranges, [PA-1 start point] and [PA-1 end point] are displayed on the
[Action] part in the [Break condition] sheet of the [Event] window.)
For measurement errors,
The measured value includes errors.
Error will occur before or after a break.