Renesas User System Interface Cable HS2633ECH61H Información técnica

Busca en linea o descarga Información técnica para Redes Renesas User System Interface Cable HS2633ECH61H. Renesas User System Interface Cable HS2633ECH61H Technical information [de] [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Pagina 2

i Preface Thank you for purchasing this user system interface cable (HS2633ECH61H) for the Renesas’ original microcomputer H8S/2633 group. The HS2633

Pagina 3 - User’s Manual

ii Contents Section 1 Configuration...1 Section 2 Connection Pr

Pagina 4 - Cautions

1 Section 1 Configuration CAUTION Use an NQPACK128RD socket (manufactured by Tokyo Eletech Corporation) for the FP-128 package IC socket

Pagina 5 - IMPORTANT INFORMATION

2 Figure 1 HS2633ECH61H User System Interface Cable

Pagina 6 - DISCLAIMER

3 Table 1 lists the HS2633ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2633ECH61H Components No.

Pagina 7

4 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Pagina 8 - SAFETY PAGE

5 Figure 2 Connecting User System Interface Cable to Emulator Station

Pagina 9

6 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Pagina 10 - Preface

7 Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an FP-128 package to the user syste

Pagina 11 - Contents

8 2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriber provided for tightening screws. 2. The tightening torque must be 0.054 N•m or less

Pagina 12 - CAUTION

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Pagina 13

9 Figure 4 Connecting User System Interface Cable to User System

Pagina 14

10 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigRemovingUser system Figure

Pagina 15

11 2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system

Pagina 16

12 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7

Pagina 17

13 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Pagina 18

14 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided f

Pagina 19

15 User systemScrews (M2 x 6 mm)IC socketTokyo Eletech CorporationNQPACK128RDSocket coverMCUPin 1 Figure 9 Installing MCU to User System

Pagina 20

16 Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2633 group, turn on the emulator according to the procedures describ

Pagina 21 - 2.2.5 Fastening Cable Body

17 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Pagina 22 - 23.00 ± 0.15

H8S/2633 Group QFP-128User System Interface Cable HS2633ECH61H User's ManualPublication Date: Rev.5.00, Janu

Pagina 23

H8S/2633 Group QFP-128User System Interface CableHS2633ECH61H User’s ManualUser’s Manual Rev.5.0 2004.01Renesas Microcomputer Development Environme

Pagina 24

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8S/2633 Group QFP-128User System Interface CableREJ10B0085-0500HHS2633ECH61H Us

Pagina 25

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better an

Pagina 26 - Screws (M2 x 6 mm)

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Pagina 27

II LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and f

Pagina 28 - Section 5 Notice

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,

Pagina 29 - User System Interface Cable

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur

Pagina 30 - HS2633ECH61H User’s Manual

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Comentarios a estos manuales