23
R01DS0139ED0100
Data Sheet
Chapter 3 Power supply specification
3.5.3 Condition 2
M1products: RESET is used
M2 products: RESET is used; WAKE and PTCTL1 are not used
Normal operating mode / Serial programming mode
Note There is no specification for _RESET rise and fall times.
Parameter Symbol Condition
Ratings
Unit
Min Typ Max
REGnVDD, IOVDD (rise) to CVDD (0V)
hold time
tR0CH 1 - - ms
REG0VDD, REG1VDD, IOVDD (rise) to
FLMD0,1(VIL) hold time
tR0MDH 1 - - ms
CVDD (rise) to _RESET (rise) tCRR 0 - - ms
FLMD0,1 (VIH or VIL1)
a
to
_RESET(VIL) (rise)
tMDRR 1 - - ms
_RESET (rise) to FLMD0,1(VIH or VIL)
hold time
tRMDH 1 - - ms
FLMD0,1,MODE0,1(VIL) to _RESET
(VIH) (fall) setup time
tMDRF 0 - - ms
_RESET (fall) to CVDD (fall) tRCF 0 - - ms
CVDD (0V) to REGnVDD, IOVDD (fall) tCR0OF 0 - - ms
_RESET (VIL) (fall) to REGnVDD,
IOVDD (fall) hold time
tRR0OF 0 - - ms
a)
In case of BSCAN mode set also the MODE0,1 pins.
REGnVDD
IOVDD
CVDD (M2)
FLMD0
P0_1/FLMD1
3.0V
tMDRRtROMDH
VIL
1.1V
tCROOF
VIL
3.0V
_RESET
1.1V
VIL
tRCF
tCRRtR0CH
tRMDH
VIH
VIH
tMDRF tRR0OF
Comentarios a estos manuales