Renesas H8S/2128 Series Manual de usuario Pagina 118

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 171
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 117
110
(2) Control Signal Timing
Table 22.19 shows the control signal timing. The only external interrupts that can operate on the
subclock (ø = 32.768 kHz) are NMI and IRQ0, 1, and IRQ2.
Table 22.19 Control Signal Timing
Condition A: V
CC
= 5.0 V ± 10%, V
SS
= 0 V, ø = 32.768 kHz, 2 MHz to maximum operating
frequency, T
a
= –20 to +75°C (regular specifications),
T
a
= –40 to +85°C (wide-range specifications)
Condition B: V
CC
= 4.0 V to 5.5 V, V
SS
= 0 V, ø = 32.768 kHz, 2 MHz to maximum operating
frequency, T
a
= –20 to +75°C (regular specifications),
T
a
= –40 to +85°C (wide-range specifications)
Condition C: V
CC
= 2.7 V to 3.6 V, V
SS
= 0 V, ø = 32.768 kHz, 2 MHz to maximum operating
frequency, T
a
= –20 to +75°C
Condition A Condition B Condition C
20 MHz 16 MHz 10 MHz
Test
Item Symbol Min Max Min Max Min Max Unit Conditions
RES setup time t
RESS
200 200 300 ns Figure 22.31
RES pulse width t
RESW
20 20 20 t
cyc
NMI setup time
(NMI)
t
NMIS
150 150 250 ns Figure 22.32
NMI hold time
(NMI)
t
NMIH
10 10 10 ns
NMI pulse width
(exiting software
standby mode)
t
NMIW
200 200 200 ns
IRQ setup time
(IRQ2 to IRQ0)
t
IRQS
150 150 250 ns
IRQ hold time
(IRQ2 to IRQ0)
t
IRQH
10 10 10 ns
IRQ pulse width
(IRQ2 to IRQ0)
(exiting software
standby mode)
t
IRQW
200 200 200 ns
Vista de pagina 117