Renesas H8S/2338 Series Información técnica Pagina 31

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 30
14
5.2
5.25.2
5.2 Diagnostic Test Procedure Using Tes
Diagnostic Test Procedure Using TesDiagnostic Test Procedure Using Tes
Diagnostic Test Procedure Using Test Program
t Programt Program
t Program
Insert the CD-R (HS2339EPI61SR supplied with the E6000) into the CD-ROM drive of the host
computer by pressing the Shift key, move the current directory to <Drive>:\Diag with a command
prompt, and enter one of the following commands according to the PC interface board used to
initiate the test program:
1. ISA bus interface board (HS6000EII01H)
>TM2339 ISA (RET)
2. PCI bus interface board (HS6000EIC01H, HS6000EIC02H)
>TM2339 PCI (RET)
3. PCMCIA interface card (HS6000EIP01H)
>TM2339 PCCD (RET)
The HDI must be installed before the test program is executed.
Be sure to initiate the test program from <Drive>:\Diag. Do not initiate it from a directory other
than <Drive>:\Diag, such as > <Drive>:\Diag\TM2339 ISA (RET). If the test program is
initiated when the current directory is not <Drive>:\Diag, the test program will not operate
correctly.
When S is added to the command line such as >TM2339 ISA S (RET), steps 1 to 18 will be
repeatedly executed. To stop the execution, enter Q.
Notes: 1. When the CD-R is inserted into the CD-ROM drive without pressing the Shift key, the
HDI installation wizard is automatically started.
In such a case, exit the HDI installation wizard.
2. <Drive> is a drive name for the CD-ROM drive.
3. Do not remove the CD-R from the CD-ROM drive during test program execution.
Vista de pagina 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36

Comentarios a estos manuales

Sin comentarios