5.2 Diagnostic Test Procedure Using the Test Program
Insert the CD-R (HS2628EPI61SR supplied with the E6000) into the CD-ROM drive of the host
computer by pressing the Shift key, move the current directory to <Drive>:\Diag with a command
prompt, and enter one of the following commands according to the PC interface board used to initiate
the test program:
1. PCI bus interface board (HS6000EIC01H or HS6000EIC02H)
> TM2628
PCI (RET)
2. PCMCIA interface card (HS6000EIP01H)
> TM2628
PCCD (RET)
3. USB adapter (HS6000EIU01H)
> TM2628
USB
4. LAN adapter (HS6000ELN01H)
> TM2628
ELN
The HDI must be installed before the test program is executed.
Be sure to initiate the test program from <Drive>:\Diag. Do not initiate it from a directory other than
<Drive>:\Diag, such as > <Drive>:\Diag\TM2628
PCI
(RET). If the test program is initiated when the
current directory is not <Drive>:\Diag, the test program will not operate correctly.
When
S is added to the command line such as > TM2628
PCI
S (RET), steps 1 to 19 will be
repeatedly executed. To stop the execution, enter Q.
Notes: 1. When the CD-R is inserted into the CD-ROM drive without pressing the Shift key, the HDI
installation wizard is automatically started.
In such a case, exit the HDI installation wizard.
2. <Drive> is a drive name for the CD-ROM drive.
3. Do not remove the CD-R from the CD-ROM drive during test program execution.