1.6 Emulation
1.6.1 Temporary Breakpoints
• Run... (Run menu)
Do not set temporary breakpoints to an area wherein PC Break (User Read-only) cannot be set. Otherwise,
user program execution will not stop at the breakpoint. Moreover, the On Chip Breakpoint may remain. In
this case, delete the breakpoint from the [Breakpoints] window.
1.6.2 Rate of Stepping
To perform stepping continuously with the [Image View] window or [Waveform] window open, select the
rate of stepping either from 0 to 5.
1.6.3 Go to Cursor
The [Go to Cursor] function uses one PC breakpoint. Note the followings:
• To use the [Go to Cursor] function, the number of PC breakpoints must be 255 or less.
• To use the [Go to Cursor] function for the ROM area on the target system, do not use the On Chip
Breakpoint by the PC break.
1.6.4 Note on Occurrence of Breaks
When a break occurs during execution of the user program with a dialog box open, the state of HEW2
may not transit to the breaking state. In this case, close the dialog box and select [Halt Program] from the
[Debug] menu or press the [Halt Program] button on the toolbar. You can check whether a break has
occurred or not by the RUN lamp (LED) on the emulator station. The RUN lamp (LED) is illuminated
while the user program is running.
1.6.5 Execution Status Display
• Execution Status Display on Status Bar
At memory access wait, not the address where the access is halted, but the next fetched address is
displayed.
1.6.6 Source-Level Execution
• Step
Even standard C libraries are executed. To return to a higher-level function, enter Step Out. In a for
statement or a while statement, executing a single step does not move execution to the next line. To move
to the next line, execute two steps.
1.7 The Load/Save of the Session File
Load the file after you confirm that the H/W environment is the same as that when the last session file was
loaded.
Note that the operation of HEW may become incorrect when Target Clock is chosen at the time when the
session file was saved and the target clock was not supplied at the time when the session file was loaded.
1.8 Assembling and Disassembling
1.8.1 [Disassembly] Window
When the [Disassembly] window is first opened after installation of the HEW2, changing the size of the
window may not be available. In this case, close the [Disassembly] window and then open it again.