Creating and Running a New Project Workspace
5.3.5 Setting Linker Options
Rev. 1.01 May 7, 2008
5-16
REJ11J0015-0101
5
(3) [Section address] dialog box shown below will be displayed. In this dialog box, enter “0x207FF000” for the
Address as shown in
Figure 5.3.11, and press “OK”.
Figure 5.3.11 Section Settings (3)
(4) The section address will be added and it returns to [Section] dialog box. Choose a blank section as shown in
Figure 5.3.12, and click “Add”.
Figure 5.3.12 Section Settings (4)