4
In the E6000, clock can be selected as shown in table 1.5 by using the Configuration window or
the Clock command.
Select the clock from a range between 4 MHz to the maximum operation frequency
φ
(MHz) (see
table 1.4). (If the frequency will not become 4 MHz or more due to the settings of the input clock
and clock multiplication, an error will occur.)
Table 1.5 Clock Selections for E6000 SH7050 Emulator
Command
Configuration
Window Setting
Item
Command Name Parameter Option name Parameter
Notes
8MHz 8MHz Initial value
8.25MHz 8.25MHz
10MHz 10MHz
Input clock Clock
Target
Clock Rate
Target Initial value at user
system connection
×1 PLL × 1 Initial value
×2 PLL × 2
×4 PLL × 4
Clock
multiplication
Clock Mode
Target*
Clock Mode
Target* Initial value at user
system connection
1 1 Initial value
22
Clock division Clock Divisor
4
Clock Divisor
4
Note: *When Target is selected for the parameter of the clock multiplication, the clock multiplication
follows the setting of the mode pins (MD3 and MD2) on the user system.
NOTE
The clock specified by the HDI Clock command or
through the Configuration window is divided or multiplied and
becomes the system clock (
φ
). Therefore system clock (
φ
) is
10 MHz when Target is selected for clock input, and a 20 MHz
crystal oscillator is connected to EXTAL, and division is 2 and
multiplication is 1.