Renesas SH7781 Información técnica Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
Section 2 Software Specifications when Using the SH7781
Rev. 2.00 Jan. 28, 2008 Page 9 of 32
REJ10J1422-0200
Section 2 Software Specifications when Using the SH7781
2.1 Differences between the SH7781 and the Emulator
1. When the emulator system is initiated, it initializes the general registers and part of the control
registers as shown in table 2.1. The initial values of the actual SH7781 registers are undefined.
When the emulator is initiated from the workspace, a value to be entered is saved in a session.
Table 2.1 Register Initial Values at Emulator Link Up
Register Emulator at Link Up
R0 to R14 H'00000000
R15 (SP) H'A0000000
R0_BANK to R7_BANK H'00000000
PC H'A0000000
SR H'700000F0
GBR H'00000000
VBR H'00000000
MACH H'00000000
MACL H'00000000
PR H'00000000
DBR H'00000000
SGR H'00000000
SPC H'00000000
SSR H'000000F0
FPUL H'00000000
FPSCR H'00040001
FR0 to FR15 H'00000000
XF0 to XF15 H'00000000
2. The emulator uses the H-UDI; do not access the H-UDI.