Document Name Page Object
Page 195
Figure 2.2.21. Set-up procedure of one-shot mode
M30201 group user’s manual
Page 197
Figure 2.2.23. Set-up procedure of one-shot mode, external
trigger selected
Document Name Page Object
M30201 group user’s manual
Page 235
Figure 2.4.15. Set-up procedure of one-shot mode
( 3 / 3 )
RENESAS TECHNICAL NEWS
No.
M16C-105-0309
Setting one-shot timer's time
(b15) (b8)
b7 b0 b7 b0
Timer A0 register [Address 0387
16
,
0386
16
] TA0
(Previous change) Can be set to 0001
16
to FFFF
16
(After change) Can be set to 0000
16
to FFFF
16
(Note 1)
Note 1. If theTA0 register is set to ‘0000
16
’, the counter does not work and timer A0 interrupt
request is not generated either. Furthermore, the output level from the TA0
OUT
pin does
not change.
Setting one-shot timer's time
(b15) (b8)
b7 b0 b7 b0
Timer X0 register [Address 0389
16
,
0388
16
] TX0
Timer X1 register [Address 038B
16
,
038A
16
] TX1
Timer X2 register [Address 038D
16
,
038C
16
] TX2
Can be set to 0000
16
to FFFF
16
(Note 1)
Note 1. If theTXi register is set to ‘0000
16
’, the counter does not work and timer Xi interrupt
request is not generated either. Furthermore, the output level from the TXi
INOUT
pin
does not change.