Renesas User System Interface Cable HS36049ECH61H Manual de usuario

Busca en linea o descarga Manual de usuario para Redes Renesas User System Interface Cable HS36049ECH61H. Renesas User System Interface Cable HS36049ECH61H User`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
2003.12.19
H8/36049 Group FP-80A User System
Interface Cable for E6000 Emulator
HS36049ECH61H User’s Manual
HS36049ECH61HE
Renesas Microcomputer Development Environment System
H8 Family / H8/300H Tiny Series
Rev.1.00
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - Rev.1.00

2003.12.19H8/36049 Group FP-80A User SystemInterface Cable for E6000 EmulatorHS36049ECH61H User’s ManualHS36049ECH61HERenesas Microcomputer Develo

Pagina 2 - Cautions

1Section 1 ConfigurationCAUTIONUse an IC149-080-017-B5 socket (manufactured byYAMAICHI ELECTRONICS Co., Ltd.) for the FP-80Apackage IC socket on th

Pagina 3 - IMPORTANT INFORMATION

2Table 1 lists the HS36049ECH61H components. Please make sure you have all of thesecomponents when unpacking.Table 1 HS36049ECH61H ComponentsNo. Comp

Pagina 4 - DISCLAIMER

3Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator Station (withChannel 3 of Serial Communication Interface for

Pagina 5

4Emulator stationCable body connectorUser system interface cableE6000CTS screws (M3 x 6 mm)Figure 2 Connecting User System Interface Cable to Emulat

Pagina 6 - SAFETY PAGE

52.2 Connecting User System Interface Cable to Expansion I/O Board(without Channel 3 of Serial Communication Interface for H8/36049Group)WARNINGAlways

Pagina 7

6Cable body connectorUser system interface cableCTS screws (M3 x 6 mm)Expansion I/O board cableUSER INTERFACE CABLE6000 EMULATOE6000Figure 3 Connect

Pagina 8

72.3 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Pagina 9 - Contents

82.3.3 Inserting Cable HeadCAUTIONCheck the location of pin 1 before inserting.Align pin 1 on the IC socket for an FP-80A package on the user system w

Pagina 10 - Section 1 Configuration

9Fasten the user system interface cable head to the IC socket for an FP-80A package on the usersystem with the four screws (M2 x 12 mm; with four flat

Pagina 11

102.3.5 Fastening Cable BodyConnect the cable body to the cable head.Cable bodyCable headRemove jigUser systemPush two remove jigs.RemovingFigure 5

Pagina 12

CautionsKeep safety first in your circuit designs!1. Renesas Technology Corp. puts the maximum effort into making semiconductor productsbetter and mor

Pagina 13 - CTS screws (M3 x 6 mm)

112.4 Recommended Dimensions for User System Mount PadFigure 6 shows the recommended dimensions for the mount pad (footprint) for the user systemwith

Pagina 14

122.5 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 7.Figure 7 Dimensio

Pagina 15 - USER INTERFACE CABL

132.6 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Pagina 16

14Section 3 Installing the MCU to the User SystemCAUTION1. Check the location of pin 1 before inserting.2. Use a Philips-type screwdriver whose head

Pagina 17 - 2.3.4 Fastening Cable Head

15MCUPin 1IC socket (IC149-080-017-B5manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2 x 8 mm)with flat washersSocket coverFigure 9

Pagina 18

16Section 4 Verifying Operation1. When using the H8/36049 group E6000 emulator (HS3664EPI61H), turn on the emulatoraccording to the procedures descr

Pagina 19 - 2.3.5 Fastening Cable Body

17Figure 10 shows the system clock oscillator on the user system interface cable and the subclockinput specifications.R2 270R1 1 MHCU04HCU04To E6000 e

Pagina 20 - 0.65 ± 0.05

18Section 5 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Pagina 21

196. The P1 short connector is used for testing. Do not remove the inserted jumper pin.P113Figure 12 P1 Short Connector

Pagina 22

H8/36049 Group FP-80A User System Interface Cable for E6000 Emulator User's ManualPublication Date: Rev.1.00, December 19, 2003Published by:

Pagina 23

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f

Pagina 24

H8/36049 Group FP-80AUser System Interface Cablefor E6000 EmulatorUser’s ManualREJ10B0097-0100H

Pagina 25

IILIMITED WARRANTY Renesas warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Pagina 26 - To E6000

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Pagina 27 - Section 5 Notice

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Pagina 28 - Figure 12 P1 Short Connector

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or

Pagina 29

iPrefaceThank you for purchasing this user system interface cable (HS36049ECH61H) for the Renesas’soriginal microcomputer H8/36049 group.The HS36049EC

Pagina 30 - User’s Manual

iiContentsSection 1 Configuration.....................1Section 2 Connection Proced

Comentarios a estos manuales

Sin comentarios