Renesas H8/36024 Manual de usuario

Busca en linea o descarga Manual de usuario para No Renesas H8/36024. Renesas H8/36024 User`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
2003.12.19
H8/36014 Group, H8/36024 Group FP-48B
User System Interface Cable for E6000 Emulator
User’s Manual
HS36014ECH64H
Renesas Microcomputer Development Environment System
Rev.2.00
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - Rev.2.00

2003.12.19H8/36014 Group, H8/36024 Group FP-48BUser System Interface Cable for E6000 EmulatorUser’s ManualHS36014ECH64HRenesas Microcomputer Developme

Pagina 2 - Cautions

1Section 1 ConfigurationCAUTIONUse an NQPACK048SD socket (manufactured by TokyoEletech Corporation) for the FP-48B package IC socketon the user sys

Pagina 3 - IMPORTANT INFORMATION

2Table 1 lists the HS36014ECH64H components. Please make sure you have all of thesecomponents when unpacking.Table 1 HS36014ECH64H ComponentsNo. Comp

Pagina 4 - DISCLAIMER

3Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator Station(H8/36014 Series)WARNINGObserve the precautions listed

Pagina 5

4Figure 2 Connecting User System Interface Cable to Emulator Station

Pagina 6 - SAFETY PAGE

52.2 Connecting User System Interface Cable to Expansion I/O Board(H8/36024 Series)WARNINGAlways switch OFF the user system and the emulatorproduct be

Pagina 7

6Cable body connectorUser system interface cableCTS screws (M3 x 6 mm)Expansion I/O board cableUSER INTERFACE CABLE6000 EMULATOE6000Figure 3 Connect

Pagina 8

72.3 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Pagina 9 - Contents

82.3.3 Inserting Cable HeadCAUTIONCheck the location of pin 1 before inserting.Align pin 1 on the IC socket for a FP-48B package on the user system wi

Pagina 10 - Section 1 Configuration

9Fasten the user system interface cable head to the IC socket for a FP-48B package on the usersystem with the four screws (M2 x 10 mm) provided. Each

Pagina 11

102.3.5 Fastening Cable BodyConnect the cable body to the cable head.Figure 5 Fastening Cable Body

Pagina 12

CautionsKeep safety first in your circuit designs!1. Renesas Technology Corp. puts the maximum effort into making semiconductor productsbetter and mor

Pagina 13

112.4 Recommended Dimensions for User System Mount PadFigure 6 shows the recommended dimensions for the mount pad (footprint) for the user systemwith

Pagina 14

122.5 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 7.±Figure 7 Dimensi

Pagina 15 - Expansion I/O board cable

132.6 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Pagina 16

14Section 3 Installing the MCU to the User SystemCAUTION1. Check the location of pin 1 before inserting.2. Use the screwdriver provided for tighteni

Pagina 17 - 2.3.4 Fastening Cable Head

15Figure 9 Installing MCU to User System

Pagina 18

16Section 4 Verifying Operation1. When using the H8/36014 series E6000 emulator (HS3664EPI61H), turn on the emulatoraccording to the procedures desc

Pagina 19 - 2.3.5 Fastening Cable Body

17Figure 10 shows the system clock oscillator on the user system interface cable.Figure 10 System Clock Oscillator

Pagina 20

18Section 5 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Pagina 21

19Figure 12 P1 Short Connector

Pagina 22

H8/36014 Group, H8/36024 Group FP-48B User System Interface Cable for E6000 Emulator User's ManualPublication Date: Rev.1.00, July 25, 2002

Pagina 23

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f

Pagina 24

H8/36014 Group, H8/36024 Group FP-48BUser System Interface Cable for E6000Emulator User’s ManualREJ10B0093-0200H

Pagina 25

IILIMITED WARRANTY Renesas warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Pagina 26

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Pagina 27

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Pagina 28 - Figure 12 P1 Short Connector

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or

Pagina 29 - User's Manual

iPrefaceThank you for purchasing this user system interface cable (HS36014ECH64H) for the Renesas’soriginal microcomputer H8/36014series.The HS36014EC

Pagina 30 - REJ10B0093-0200H

iiContentsSection 1 Configuration.....................1Section 2 Connection Proced

Comentarios a estos manuales

Sin comentarios