(c) 2008. Renesas Technology Corp., All rights reserved.
Page 1 of 2
Date: Mar.26.2008
RENESAS TECHNICAL UPDATE
Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan
Renesas Technology Corp.
Product
Category
MPU&MCU
Document
No.
TN-H8*-A381A/E Rev. 1.00
Title
H8SX/1658R and 1668R Group
Note on activation of the A/D converter by an external
trigger
Information
Category
Technical Notification
Lot No.
Applicable
Product
H8SX/1658R, H8SX/1654R, H8SX/1653R,
H8SX/1668R, H8SX/1664R, H8SX/1663R
All lots
Reference
Document
H8SX/1658R Group Hardware Manual
(REJ09B0413-0100)
H8SX/1668R Group Hardware Manual
(REJ09B0412-0100)
We would like to inform you of a point regarding usage of the A/D converter of the H8SX/1658R and 1668R Group
products. Please take this information into consideration when using the products.
When starting of the A/D converter by an external trigger is in use, stopping of the A/D converter may not be
possible when any of the following ((1) to (3)) is executed.
*1 External trigger: Conversion-start trigger from the ADTRG input pin or peripheral modules (TMR and TPU)
(1) Changing the value of the ADST bit in the ADCSR register from 0 to 1
(2) Changing from the activation by external trigger setting to the external-trigger-disabled setting
(3) Changing the scan-mode setting (changing the setting of the SCANE and ADSTCLR bits to switch
from continuous scan mode to single mode or one-cycle scan mode)
If any of the above situations is relevant, please make settings in accord with the instructions below.
If case (1) is applicable:
Do not set 1 to the ADST bit in ADCSR register.
If case (2) or (3) is applicable:
Be sure to invalidate the external trigger input before changing the setting from activation by the external trigger to
disabling of the external trigger or changing the scan-mode setting (changing the setting of the SCANE and
ADSTCLR bits) while activation by the external trigger is in use.
Setting the TRGS1, TRGS0, and EXTRGS bits in the ADCR register to the values given overleaf invalidates the
external trigger input for the start of A/D conversion.
See flowchart 1 for details of the procedure in the event of (2) or (3).