RENESAS TECHNICAL UPDATE TN-H8*-A381A/E Date: Mar.26.2008
P
age 2 of 2
Flowchart 1 Procedure for changing modes when starting of the A/D converter by an external trigger
signal has been selected
*2 Ensure that the TTGE bit in TIER of TPU unit 1 is set to 0 before making these settings, as is specified on page
604(H8SX1658R Group),706(H8SX1668R Group) of the hardware manual.
*3 Ensure that the TRGS1, TRGS0, and EXTRGS bits in the respective ADCR registers are set (as bytes) at the
same time.
Unit 0
External trigger
shut off?
ADCSR_ADST = 0
Change the scan mode.
Yes
No
ADCR_TRGS1 = 0
ADCR_TRGS0 = 0
ADCR_EXTRGS = 1
Unit 1
ADCR_TRGS1 = 0
ADCR_TRGS0 = 1
ADCR_EXTRGS = 1
Change the external trigger
setting.
*
3
External trigger
shut off?
ADCSR_ADST = 0
Change the scan mode.
Yes
No
Yes
No
ADCR_TRGS1 = 0
ADCR_TRGS0 = 0
ADCR_EXTRGS = 1
Invalidates the external trigger
*
3
ADCR_TRGS1 = 0
ADCR_TRGS0 = 1
ADCR_EXTRGS = 1
Yes
No
Change the external trigger
setting.
*
3
Invalidates the external trigger
*
2, 3