3.2 Selecting Clock Supply
There are two ways to supply a clock to the MCU, using the oscillator circuit in the emulation pod
or using the oscillator circuit on the target system. Table 3.1 shows the factory-settings of each clock
supply.
Table 3.1 Clock supply to the MCU
IMPORTANT
Notes on Changing the Clock Supply:
The clock supply can be set by the Init dialog box when starting up the emulator
debugger or inputting CLK command on the script window.
For pins XCIN-XCOUT, it is necessary to set the switches on the FLX64-PRB board. For
details, refer to the user's manual of pod probe.
Clock Description Display of emulator debugger Factory-setting
X
IN-XOUT
XCIN-XCOUT
Internal oscillator circuit of emulation pod
(OSC-3: 16 MHz)
Target system
Internal oscillator circuit of emulation pod
(32.768 KHz)
Target system
Internal
External
External
Internal
Yes
-
-
Yes