5
When the circuit is connected as shown in figure 1.2, the switches of the emulator are set as SW2
= 1 and SW3 = 1. For details, refer to section 3.8, Setting the DIP Switches, in the Debugger Part
of the SuperH
TM
Family E10A-USB Emulator User’s Manual.
1
TCK
TMS
RESET
TDI
TDO
TRST
N.C.
GND
GND
GND
GND
(GND)
2
3
4
5
6
7
ASEMODE
8
9
11
10
12
13
14
TCK
RES
TMS
TDO
TDI
TRST
VccQ
N.C.
VccQ
VccQ
VccQ
UVCC
VccQ
H-UDI port connector
(14-pin type)
Reset signal
Pulled-up at 4.7 k or more (all)
User system
VccQ = 3.3 V (I/O power supply)
SH7619
1 k
Figure 1.2 Recommended Circuit for Connection between the H-UDI Port Connector and
MPU when the Emulator is in Use (14-Pin Type UVCC Connected)