SH7080 Group
A/D Conversion in Single-cycle Scan Mode
REJ06B0699-0100/Rev.1.00 January 2008 Page 4 of 19
3. Description of Modules Used
In this sample application, A/D converter channels 0 to 3 are used for A/D conversion.
The functions of the SH7080 group A/D converter are outlined in table 2.
Table 2 A/D Converter Function Overview
Item Overview
Resolution 10 bits
Input channels
8 channels (2 independent A/D conversion modules on chip) for the SH7083/84/85
16 channels (3 independent A/D conversion modules on chip) for the SH7086
Conversion time
2.0 µs per channel (when Pφ = 25 MHz)
Operation mode
Single mode: A/D conversion on one channel
Continuous scan mode: A/D conversion repeated on up to 4 channels for the
SH7083/84/85 or up to 8 channels for the SH7086
1-cycle scan mode: A/D conversion repeated on up to 4 channels for the
SH7083/84/85 or up to 8 channels for the SH7086
Data register
Results of A/D conversion are stored in 16-bit data registers corresponding to the
respective input channels.
A
/D conversion start
method
Operation of the A/D control register (ADCR) by software
A/D converter start trigger from the multi-function timer pulse unit 2 (MTU2) or 2S
(MTU2S) can be selected.
External trigger signal
Interrupt source
A/D conversion end interrupt request (ADI)
Others
Sample & hold functions are provided.
Module standby mode can be set.
DMAC/DTC can be started by an interrupt.