M38000T2-CPE User’s Manual 5. Troubleshooting
REJ10J0301-0400 Rev.4.00 March 01, 2006
Page 73 of 78
(2) MCU Setting Dialog Box Does Not Appear at Debugger Startup
Table 5.2 Checkpoints of errors at debugger startup
Error Checkpoint
Cannot connect with the target.
The emulator debugger cannot be connected to the emulator properly.
- Check that the emulator's target status LEDs. If they are blinking, the
emulator has not started up properly. Check the settings explained in "5.2
(1) When the LEDs of the M38000T2-CPE Do Not Display Normally"
(page 73).
- Check that the USB cable is connected properly.
- Check that the USB driver is installed properly.
Target MCU is not under control.
Please execute RESET command.
The emulator MCU does not work properly because of some kind of problem.
- Recheck the connection of the emulator.
- Check the clock, reset circuit and power supply of the user system.
Target Missing or Connection Controlled.
Contact your local distributor.
Communication error occurred.
Data was not sent to the target.
- Check the target status LED display. If the LED is blinking, the emulator did
not start up normally.
See “2.6.9 LED Display When the Emulator Starts Up Normally” (page 29).
- Check that the USB cable is connected properly.
See "2.5 Connecting the Host Machine " (page 24).