24 www.ngxtechnologies.com
Step 3: When execution of the [Program] command ends normally, “Image written to device” and
“Disconnected” are displayed on the output panel.
Figure 4-16. [Program] Command Execution Results
(7) System shutdown
Step 1: Disconnect the target cable from the target system.
Remark
When supplying VDD power to the target system, turn off the power before removing the target
cable. Furthermore, if [Auto Disconnect] in the [Flash Program Options] category in the [Other
Settings] tab of the [List of Settings] dialog box is set to “False,” remove the target system after
Executing [Disconnect To Device].
Step 2: Unless there are other target microcontrollers to be programmed, click the [File] menu and select
the [Exit] command to close RFP. Because all settings made so far will be saved to a project file, they
can be reused after RFP is restarted.
Step 3: Remove the USB cable from the tool used.
Step 4: To execute the user code supply power using USB cable to the target board and set Boot switch
to 1100 then LED (D2) should blink.
Caution:
If an error occurs during the above procedure, see section TROUBLESHOOTING. Also see the
user’s manual of the tool used and execute diagnostic tests.