Rev. 1.0, 07/03, page 19 of 38
2.1.9 HM5257165B-A6 (8 Mwords × 16 bits × 4 banks)
Bus State Controller (BSC) Settings: When an SDRAM (HM5257165B-A6) is connected to
area 3 of the SH7709S/SH7729R/SH7706 via a 16-bit bus, the bus state controller (BSC) must be
specified as summarized below. Table 2.7 lists the BSC register settings.
Note that the interface between SDRAM and the SH7709S/SH7729R/SH7706 is performed with
bus clock = 66 MHz, CL = 2, TPC = 2, RCD = 2, TRWL = 1, and TRAS = 4.