E8a Emulator User's Manual 5. Debugging
5.4.25 Deleting Break Conditions
Select a break condition and choose [Delete] from the popup menu to remove the selected break
condition. To retain the break condition but not have it cause an event when its conditions are met,
use the [Disable] option (see section 5.4.24, Disabling Break Conditions).
5.4.26 Deleting All Break Conditions
Choose [Delete All] from the popup menu to remove all break conditions.
5.4.27 Viewing the Source Line for Break Conditions
Select a break condition and choose [Go to Source] from the popup menu to open the [Source] or
[Disassembly] window at the address of the break condition. The [Go to Source] menu is only
available when one break condition that has the corresponding source file is selected.
5.4.28 [Break condition x] Dialog Box
Figure 5.8 [Break condition 3] Dialog Box
This page sets the address bus, data bus, and read/write cycle conditions.
Note: The items that can be set in this dialog box differ depending on the product. For the
settings for each product, refer to the online help.
REJ10J1655-0400 Rev.4.00 Page 89 of 158