Vista de pagina 16
Shelf interfaces
2
17
Figure 5. Reset input connection—External connection to external equipment
Shelf interfaces
The following shelf I/Os are monitored by the SPM through a 3x32 pin connector.
Thermal sensors
The SPM supports thermal sensors located in the shelf through an I
2
C bus.
Air filter switch sensors
The SPM monitors two air filter switches mounted so that the switches open if the air filter is
improperly installed, misaligned, or removed. This function tells the system software when the
air filter is installed properly in the shelf.
iButton
One digital I/O connects to an iButton on the backplane. The iButton stores shelf FRU and other
information.
Shelf display panel
The SPM provides an I
2
C interface to the SDP and monitors the SDP presence and alarm
acknowledge signals.
{
Driven to reset
minor alarms
2
1
{
Driven to reset
major alarms
4
3
SPM 1 SPM 2
Opto-
isolator
+
Opto-
isolator
+
2
1
4
3
Opto-
isolator
+
Opto-
isolator
+
+
+