Renesas H8S/2138 Series Manual Pagina 49

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 148
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 48
Microcomputer Technical Q&A
41
Q&A No.: QAH8S-035
Category: Bus Controller
Subject: Program Wait Switchover Timing
Question
After a power-on reset, 3 program wait states are inserted in an external access cycle, making a 6-
state access. When external 3-state access is set, what is the switchover timing?
Answer
The switchover is made immediately after the wait control register (WCRH) is set. To set external
3-state access after a power-on reset, clear the Wn0 and Wn1 bits in WCR to 0.
An example of the switchover timing when waits are disabled by clearing all WCR bits to 0 with a
MOV instruction is shown below.
Example: MOV.W R1,@H'FED2:16
WCRH (address H'FED2), WCRL (address H'FED3) (assuming 0 is stored in R1)
3 states + 3 waits 3 states + 3 waits 2 states 3 states
R:W 2nd R:W NEXT W:W EA
MOV.W R1,@FED2:16
Address
RD
HWR, LWR
Vista de pagina 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 147 148

Comentarios a estos manuales

Sin comentarios