Renesas Single-Chip Microcomputer M37531T-ADS Información técnica Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 57
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
Location: Hardware, timer X (exist in M30201 Group), pulse period/pulse width measurement mode
Error: The timer Xi overflow flag changes to "0" when the count start flag is "1" and a value is written
to the timer Xi mode register.
Correction: Assume that the count start flag condition is "1" and then the Timer Xi overflow flag
becomes "1". If the Timer Xi mode register has a write-access after next count cycle of
the timer from the above condition, the Timer Xi overflow flag becomes "0".
Location: Peripheral functions usage, timer B, pulse period measurement mode
Error: The timer Bi overflow flag goes to "0" if timer Bi mode register is written to when the count start
flag is "1".
Correction: Assume that the count start flag condition is "1" and then the Timer Bi overflow flag
becomes "1". If the Timer Bi mode register has a write-access after next count cycle of
the timer from the above condition, the Timer Bi overflow flag becomes "0".
Location: Peripheral functions usage, timer B, pulse width measurement mode
Error: The timer Bi overflow flag goes to "0" if timer Bi mode register is written to when the count start
flag is "1".
Correction: Assume that the count start flag condition is "1" and then the Timer Bi overflow flag
becomes "1". If the Timer Bi mode register has a write-access after next count cycle of
the timer from the above condition, the Timer Bi overflow flag becomes "0".
Location: Peripheral functions usage, precautions for timer B, pulse period/pulse width measurement mode
Error: When reset, the timer Bi overflow flag goes to "1". This flag can be set to "0" by writing to the
timer Bi mode register when the count start flag is "1".
Correction: After reset, the Timer Bi overflow flag is undefined. Under this condition, assume that the
count start flag is set to "1" and then the Timer Bi mode register has a write-access after
the timer starts counting. Therefore, the Timer Bi overflow flag becomes "0".
Location: Peripheral functions usage, timer X (exist in M30201 Group), pulse period measurement mode
Error: The timer Xi overflow flag goes to "0" if timer Xi mode register is written to when the count start
flag is "1".
Correction: Assume that the count start flag condition is "1" and then the Timer Xi overflow flag
becomes "1". If the Timer Xi mode register has a write-access after next count cycle of
the timer from the above condition, the Timer Xi overflow flag becomes "0".
Location: Peripheral functions usage, timer X (exist in M30201 Group), pulse width measurement mode
Error: The timer Xi overflow flag goes to "0" if timer Xi mode register is written to when the count start
flag is "1".
Correction: Assume that the count start flag condition is "1" and then the Timer Xi overflow flag
becomes "1". If the Timer Xi mode register has a write-access after next count cycle of
the timer from the above condition, the Timer Xi overflow flag becomes "0".
Location: Peripheral functions usage, precautions for timer X (exist in M30201 Group), pulse period/pulse
width measurement mode
Error: When reset, the timer Xi overflow flag goes to "1". This flag can be set to "0" by writing to the
timer Xi mode register when the count start flag is "1".
Correction: After reset, the Timer Xi overflow flag is undefined. Under this condition, assume that the
count start flag is set to "1" and then the Timer Xi mode register has a write-access after
the timer starts counting. Therefore, the Timer Xi overflow flag becomes "0".
No.M16C-75-0110
( 2 / 2)
Vista de pagina 54
1 2 ... 50 51 52 53 54 55 56 57

Comentarios a estos manuales

Sin comentarios