( 43 / 74 )
3.9 Connecting the User System
Connect the emulation pod to the user system as shown in Figure 3.14.
(1) Mount the NQPACK116SB to the user system.
(2) Attach the YQPACK116SB to the NQPACK116SB.
(3) Fix the YQPACK116SB with the included YQ-GUIDE's.
(4) Attach the CN2 side of the M306H2T-PTC to the tip (CN2 side) of the pitch converter board
FLX160-PRB connected to the emulation pod probe.
(5) Attach the M306H2T-PTC to the fixed YQPACK116SB.
CAUTION
Notes on Connecting the User System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
Figure 3.14 Connecting the user system
M3T-FLX160C
FLX160-PRB (premounted on M3T-FLX160C)
M306H2T-PTC
YQ-GUIDE's (x4)
YQPACK116SB
Onboard evaluation
HQPACK116SB
(separately available)
MCU
NQPACK116SB
116-pin 0.65-mm-pitch
(116P6A-A) foot pattern
User system
No. 1 pin
This corner is not round.
This corner is not round.
* These four parts are in one package.
(1)
(2)
(3)
(5)
*
(4)
CN2
CN1