E8a Emulator User's Manual 11. Appendix E: E8aSCP (E8a Self-Check Program)
R20UT0541EJ0601 Rev.6.01 Page 121 of 124
Aug 25, 2011
Table E.1 Error Messages
Error Message Description
The E8a has failed. The E8a emulator has become faulty.
If this applies to the contents guaranteed in 'IMPORTANT' described in this
user's manual, we will repair or replace your faulty product free of charge.
If this guarantee does not apply to your product's fault, we will repair the
product or replace it with a new one with extra-charge. However, replacement
will be lower in cost and we recommend that you purchase a new emulator.
Please connect the User interface cable
with the self-check connector in a correct
direction.
Connect the user system interface cable to the self-check connector in the
correct direction, as shown in Figure E.2, before running the self-check
program.
Because the User interface cable was
connected with to self-check connector,
TEST3 was interrupted.
Perform the self-check again from the
beginning.
Execution of TEST3 was halted because the user system interface cable was
not removed from the self-check connector before starting ‘TEST3 is running.’
Connect the user system interface cable to the self-check connector in the
correct direction, as shown in Figure E.2, and restart the self-check program
from the beginning.
An error occurred during USB I/O
processing.
The USB cable was disconnected during execution of the self-check program,
or the E8a emulator became faulty. Execute the self-check program again.
If this error message is displayed again, the emulator could be faulty.