E8a Emulator User's Manual 5. Debugging
R20UT0541EJ0601 Rev.6.01 Page 78 of 124
Aug 25, 2011
5.6 Using the Start/Stop Function
The emulator executes the specified routine of the user program immediately before starting and immediately after halting
program execution. This function is used to control the user system in synchronization with execution and halting of the
user program.
Note: The start/stop function is not supported in the H8/Tiny or H8/Super Low Power series, the 740 family, or the
R8C/10, R8C/11, R8C/12, or R8C/13 group.
5.6.1 Opening the [Start/Stop Function Setting] Dialog Box
The
routine
executed immediately before starting and immediately after halting the user program execution is specified in
the [Start/Stop Function Setting] dialog box.
To open the [Start/Stop Function Setting] dialog box, choose [Setup -> Emulator -> Start/Stop Function Setting…] from
the [Start] menu.
Figure 5.10 [Start/Stop Function Setting] Dialog Box
5.6.2 Specifying the Routine to be Executed
It is possi
ble to specify the respective routines immediately before starting and immediately after halting the user program
execution.
When the [The specified routine is executed immediately before execution of the user’s program.] check box is selected,
the routine specified in the [starting address] combo box, which is below this check box, is executed immediately before
starting user program execution.
If no specified routine is executed immediately before starting user program execution, do not select the [The specified
routine is executed immediately before execution of the user’s program.] check box.
When the [The specified routine is executed immediately after the stop of the user’s program.] check box is selected, the
routine specified in the [starting address] combo box, which is below this check box, is executed immediately after halting
user program execution.
If no specified routine is executed immediately after halting user program execution, do not select the [The specified
routine is executed immediately after the stop of the user’s program.] check box.