Vista de pagina 34
M3062PT2-EPB User’s Manual 2. Setup
R20UT0211EJ0300 Aug 16, 2012 Page 35 of 104
Rev.3.00
2.9.4 Connecting to a 100-pin 0.65-mm-pitch Foot Pattern (Part 2)
Here follo
wing is a procedure of connecting to a 100-pin 0.65-mm-pitch foot pattern on the user system using the M3T-
DIRECT100S (not included) (discontinued). For details on the M3T-100LCC-DMS (not included) and M3T-DIRECT100S
(not included), refer to each user's manual.
(1) Attach the M3T-DIRECT100S to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-DIRECT100S.
(3) Attach the CN2 side of the M30800T-PTC to the J4 side of the M3062PT2-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
M3T-100LCC-DMS
(not included)
CN2 side
(3)
(4)
M30800T-PTC
(2)
(1)
100-pin 0.65-mm-pitch
No. 1 pin
User system
M3T-DIRECT100S
(not included) *
M3T-FLX160-EPB
M3062PT2-EPB
(PRQP0100JB-A) foot pattern
* Discontinued product
Figure 2.11 Connecting to a 100-pin 0.65-mm-pitch foot pattern (Part 2)
CAUTION
Notes on Connecting the User System:
Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the emulator and
user system.
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.
The connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20
insertion/removal iterations.