10.6. Memory error occurs when programming
Memory error occurs when the S550-SFWv3 main unit ROM is damaged.
Following shows how to resolve.
Download
Download the programming data again.
Initialize and download
Click the “Initialize” button, or press and hold the S550-SFWv3 main unit “START” switch. Then download the
programming data again.
10.7. Mode entry error occurs when programming R8C Family
Are you not using 14pin-10 pin connecting cable? For R8C Family, 14pin-10pin connecting cable cannot be
used. Use 14pin-14pin connecting cable.
10.8. Nothing is displayed on the center display
Isn’t it set to the power saving mode? In order to turn on the center display, remove the check in the “Enable
Power Save Mode” box in the maintenance screen.
10.9. I only can select “Erase/Program/Verify” or “Verify” for the execution process.
Isn’t it set in the normal mode? Check “Enable Expansion Action Mode” box in the maintenance screen in order
to select either “Blank/Program/Verify”, “Erase/Blank/Program/Verify”, “Erase/Program”, ”Erase/Blank” ,
Blank” and “Chip Erase”.
10.10. Forgot the password for uploading
If you lose your password, set a new password and download the data to program again.
10.11. I can’t select the data when stand-alone programming in power saving mode.
With the power saving mode set, S550-SFWv3 main unit center display does not turn on, and “FUNC” switch is
invalidated. Thus, only the data with the smallest data number can be programmed in stand-alone programming.
Serial Flash Programmer[S550-SFWv3] Operation Manual 115