Renesas SuperH SH7600 Series Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
11
2.2.1
Break Condition Functions
In the emulator, four break conditions can be set (Break Condition 1,2,3,4). Table 2.3 lists the
items that can be specified for each.
Table 2.3 Types of Break Conditions
Break Condition Type Description
Address bus condition (Address) Breaks when the SH7616 address bus value matches the
specified value.
Data bus condition (Data) Breaks when the SH7616 data bus value matches the
specified value. Byte, word, or longword can be specified as
the access data size.
Read or write condition (Read or
Write)
Breaks in the read or write cycle.
Access type condition Breaks when the bus cycle is the specified cycle.
Count condition Breaks when the conditions set are satisfied the specified
number of times.
Table 2.4 lists the combinations of conditions that can be set under Break Condition 1,2,3,4.
Table 2.4 Dialog Boxes for Setting Hardware Break Conditions
Condition
Dialog Box
Address Bus
Condition
([Address] page)
Data
Condition
([Data] page)
Access Type
Condition, Read
or Write Condition
([Bus state] page)
Count Condition
([Count] page)
[Break Condition 1,2]
dialog box
OOOO
[Break Condition 3,4]
dialog box
O
X
O
X
Note: O: Can be set by checking the radio button in the dialog box.
X: Cannot be set in the dialog box.
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 23

Comentarios a estos manuales

Sin comentarios