12
Table 2.5 lists the combinations of conditions that can be set under BREAKCONDITION_SET
commands.
Table 2.5 Commands for Setting Software Breakpoints
Condition
Channel
Address Bus
Condition
(<addropt>
option)
Data
Condition
(<dataopt>
option)
Access Type
Condition
(<accessopt>
option), Read or
Write Condition
(<r/wopt> option)
Count Condition
(<Countopt>
option)
Break Condition 1,2
OOOO
Break Condition 3,4
O
X
O
X
Note: O: Can be set by the BREAKCONDITION_SET command.
X: Cannot be set by the command.
2.2.2 Trace Functions
The trace function when using the SH7616 uses the branch-instruction trace function in the
SH7616. It displays the branch-source and branch-destination addresses, the mnemonic, operand,
and trace information can be acquired in realtime.
Notes: 1. The trace information on the four latest branch instructions can be acquired. This
includes the information when execution branches from the emulator program to the
user program. Therefore, when four or more branches occur, the four latest branch
instructions are acquired; when three or less branches occur, the information on the
branch from the emulator program to the user program is displayed.
2. The emulator address may be displayed in the [Trace] window at the last address when
the user program is stopped. In such a case, the following message will be displayed.
Ignore this address because it is not a user-program-related address.
*** EML ***
2.2.3 Notes on Using the JTAG Clock (TCK)
1. Set the JTAG clock (TCK) frequency to lower than the frequency of the SH7616 peripheral
module clock (CKP).
2. Do not set 20 MHz for the JTAG clock (TCK).