M306H5T3-RPD-E User’s Manual 2. Setup
REJ10J0866-0100Z Rev.1.00 Dec.16, 2004
Page 28 of 66
2.4.2 Jumper Switches JP2 to JP9 on the M306H5T3-PRT Board (MCU-dependent)
Table 2.4 Switch settings of the M306H5T3-RPD-E (3)
Signal Switch Setting of jumper switches
FLX FLX
INT INT
CVIN1
JP2
Connects pin CVIN1 to the user
system via the M3T-FLX160C.
Connects pin CVIN1 to internal
circuit of the M306H5T3-PRT.
(Factory-setting)
FLX FLX
INT INT
SYNCIN
JP3
Connects pin SYNCIN to the user
system via the M3T-FLX160C.
Connects pin SYNCIN to internal
circuit of the M306H5T3-PRT.
(Factory-setting)
FLX FLX
INT INT
SVREF JP4
Connects pin SVREF to the user
system via the M3T-FLX160C.
Connects pin SVREF to variable
resistor VR1 on the M306H3T3-PRT.
(Factory-setting)
FLX FLX
INT INT
TEST3
JP5
Pin TEST3 is fixed to High.
Connects pin TEST3 to the user
system via the M3T-FLX160C.
(Factory-setting)
INT
INT
FLX FLX
VCC1 JP6
Connects pin VCC1 of MCU to the
internal power supply of pod
(equipotential of VCC2).
Connects pin VCC1 of MCU to the
user system. Be sure to use this
setting when the potentials of VCC1
and VCC2 are different.
(Factory-setting)
VDD2 V50/TVDD
VDD2
V50/TVDD
VDDAna JP7
Do not use this setting.
Be sure to use this setting.
(Factory-setting)