M306H5T3-RPD-E User’s Manual 3. Usage
REJ10J0866-0100Z Rev.1.00 Dec.16, 2004
Page 40 of 66
3.4 Self-check
3.4.1 Self-check Procedure
To run the self-check of the emulator, do so as explained here below. While the self-check is in progress, the LEDs will change
as shown in Figure 3.4.
(1) If the user system is connected, disconnect it.
(2) Set the switches in the emulation pod to the factory settings as shown in Figure 3.3.
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator front panel to switch
the emulator to maintenance mode.
(4) Check the SAFE LED starts blinking and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 40 seconds, the self-check has terminated normally.
Figure 3.3 Switch settings for the self-check (factory-settings)
3.4.2 If an Error is Detected in the Self-check
f the self-check does not result normally (system status error or target status error in Figure 3.4), check the following.
Whether the emulation pod and PC4701 are connected properly
Whether the proper firmware has been downloaded
Whether the switch settings of this product are the factory-settings (Figure 3.3)
IMPORTANT
Note on Self-check:
If the self-check does not result normally (excluding user system error), the emulation pod may be
damaged. Then contact your local distributor.
SW1 SW2
SW4
SW3
SW5 SW6
H
L
OPEN
L
H
OPEN
L
H
OPEN
P87
Xcin
OPEN
Xout
P86/
Xcout
OPEN
JC1_R
JP2 JP3
FLX
INT
JP6
INT
FLX
VDD2 V50/TVDD
V50 TVDD
JP5
FLX
INT
JP4
INT
FLX
INT
FLX
JP7
JP8
JP9
Comentarios a estos manuales