M306H5T3-RPD-E User’s Manual 3. Usage
REJ10J0866-0100Z Rev.1.00 Dec.16, 2004
Page 36 of 66
3. Usage
This chapter describes the setting when you use this product for the first time and the workflow, from turning on the power of
this product to starting up the emulator debugger.
.
3.1 When Using This Product for the First Time
3.1.1 Making an MCU File
It is necessary to make an MCU file to use this product with the emulator debugger M3T-PD30. According to the MCU you
use, change the contents of the MCU file. Make the MCU file following the description below using a text editor and store it in
the "mcufiles" folder in the directory where the emulator debugger is installed.
The MCU file contains information such as, SFR area, internal RAM area, internal ROM area, firmware file name. The
contents of the MCU file when using the M306H5FGFP (8KB RAM, 256KB ROM) are as follows:
0 : SFR area Start address
3FF : End address
400 : Internal RAM Start address
23FF : End address
C0000 : Internal ROM Start address
FFFFF : End address
M30620P : Name of firmware (Do not change.)
0 : Expansion No. (Do not change.)
When using this product in microprocessor mode, set the internal ROM area as follows.
00000 : Internal ROM Start address
00001 : End address
3.1.2 Setting the Work Area
With this product, the emulator uses 54 bytes as a work area in emulation memory. Therefore, according to the memory
mapping of the MCU you use, specify the work area addresses.
In single-chip mode, set the work area address at 10000h.
In memory expansion or microprocessor mode, the areas listed below cannot be used as a work area, specify a work area other
than the areas listed below. And the top address of the work area should be an even-numbered address.
(1) SFR area (0000h--003FFh)
(2) External area of multiplex bus setting
(3) Reserved area of 27000h--27FFFh
(4) Stack area used by the emulator for reset command execution (0FFF9h--0FFFFh)
The area used as a work area (54 bytes) is specified in the F/W and Work Area tab of the INIT dialog box of the emulator
debugger M3T-PD30. And set the work area as MAP=INT.