M306H5T3-RPD-E User’s Manual 2. Setup
REJ10J0866-0100Z Rev.1.00 Dec.16, 2004
Page 35 of 66
2.9 Connecting the User System
Connect the emulation pod to the user system as shown in Figure 2.14.
(1) Mount the NQPACK116SB to the user system.
(2) Attach the YQPACK116SB to the NQPACK116SB.
(3) Fix the YQPACK116SB with the included YQ-GUIDE's.
(4) Attach the CN2 side of the M306H2T-PTC to the tip (CN2 side) of the pitch converter board FLX160-PRB connected to
the emulation pod probe.
(5) Attach the M306H2T-PTC to the fixed YQPACK116SB.
Figure 2.14 Connecting the user system
CAUTION
Note on Connecting the user system:
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the
emulation pod.
IMPORTANT
Note on Connector of the Converter Board:
The connectors of the FLX160-RPB and M306H2T-PTC are guaranteed for only 50 insertion/removal
iterations.
FLX160-PRB (premounted on M3T-FLX160C)
M306H2T-PTC
YQ-GUIDEs (x 4)
YQPACK116SB
NQPACK116SB
M3T-FLX160C
CN2
CN1
User system
*
* These four parts are in one package.
116-pin 0.65-mm-pich
(116P6A-A) foot pattern
No.1 pin
(1)
(2)
(5)
(4)
(3)
HQPACK116SB
(not included)
MCU
Onboard evaluation
This corner is not round
This corner is not round