E1/E20 Emulator Setup
R20UT0398EJ0400 Rev.4.00 Page 25 of 39
May 16, 2014
2.5. Connecting System Ground
The emulator's signal ground is connected to the user system's signal ground.
In the emulator, the signal ground and frame ground are connected.
In the user system, connect the frame ground only; do not connect the signal ground to the frame ground (Figure
2.6).
If it is difficult to separate the frame ground from the signal ground in the user system, set the GND for DC power
input (AC adapter) of the host computer and the frame ground of the user system as the same potential. If the GND
potential is different between the host computer and the user system, an overcurrent will flow in the low-
impedance GND line and thin lines might be burned.
WARNING
Connecting System Ground :
Separate the frame ground from the signal ground at the user system. Failure to do so will result in
smoke, fire, or an electric shock due to the difference in ground potential.
USB
E1/E20 emulator
Logic
Power
supply
Host
computer
Signal ground
Signal ground
Signal
Frame ground
User system
Signal ground
Signal
Logic
Figure 2.6 Connecting System Ground
For a debugging environment where there is a GND gap between the user system and host PC, use the isolator
for the E1 emulator (R0E000010ACB10 / R0E000010ACB20
) or the isolator for the E20 emulator
(R0E000200ACB10) that are separately available from Renesas.