53
(2) [Other] page
Figure 3.28 [Trace Acquisition] Dialog Box ([Other] Page)
[When trace-buffer full]: Selects an action to take when the trace buffer becomes full.
[No action]: Overwrites the oldest information in the trace buffer.
[Stop trace]: Stops trace acquisition without stopping the user program execution.
[Stop execution and trace]: Stops the user program execution.
[Time measurement unit]: Selects the minimum time unit for the time stamping of the bus trace information.
[52us]: Time stamping is in minimum time units of 52 μs.
[1.6us]: Time stamping is in minimum time units of 1.6 μs.
[20ns]: Time stamping is in minimum time units of 20 ns.
[Clock]: Time stamping is in terms of the number of bus-clock cycles, i.e., is
synchronized with the cycles of the system clock signal (φ).
[Clock/2]: Time stamping is in terms of the number of bus-clock cycles, i.e., is
synchronized with 1/2 cycle of the system clock signal (φ).
[Clock/4]: Time stamping is in terms of the number of bus-clock cycles, i.e., is
synchronized with 1/4 cycle of the system clock signal (φ).