5.4 Executing Your Program
5.4.1 Step Execution
Break conditions are ignored during step execution, but trigger pulses will be output.
5.5 Event Functions
5.5.1 Software Breakpoints
A software breakpoint is realized by replacing the instruction at the specified address with a special
instruction. Accordingly, it can only be set to the area including the emulation RAM. Note that it cannot be
set to the following addresses:
Addresses whose memory content is H'0000
Do not modify the contents of the software breakpoints addresses by the user program.
The content of a software breakpoint address is replaced by a break instruction during user program
execution.
The maximum number of software breakpoints and temporary PC breakpoints in [Temporary PC
Breakpoints] of the [Run Program] dialog box is 255 in total. Therefore, when 255 software breakpoints
have been set, no temporary breakpoint set in [Temporary PC Breakpoints] of the [Run Program] dialog box
is valid. Ensure that the total number of software breakpoints and temporary PC breakpoints are 255 or less.
Do not set a breakpoint immediately after a delayed branch instruction (at a slot instruction). If this is
attempted, a slot illegal instruction interrupt will occur when the delayed branch instruction is executed, and
the break will not occur.
5.5.2 On-Chip Break
The satisfaction count can only be set for channel 4.
A reset point is only valid when a sequential break is enabled.
If a sequential break and a break range ([Address Range Break]) have been specified together, only a
sequential break is enabled.
The address and data conditions are satisfied on the bus cycles where the values on the address bus or data
bus match. Consider the following points when setting these conditions.
Longword access
Longword data is read and written in a single bus cycle. A data condition is only valid for a longword
access when specified as longword. The specified address must be a multiple of four. Note that longword
data is only valid as the size of an access.
Word access
Word data is read and written in a single bus cycle. The specified address must be a multiple of two.
Word data is only valid as the size of an access.
Byte access
Byte data is read and written in a single bus cycle. A data condition is only valid for a byte access when
specified as byte. Any address condition, both an even and odd address, are valid.