Renesas H8S/2111B Manual de usuario Pagina 328

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 582
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 327
Rev. 1.00, 05/04, page 294 of 544
Table 13.4 Flags and Transfer States (Master Mode)
MST TRS BBSY ESTP STOP IRTR AASX AL AAS ADZ ACKB ICDRF ICDRE State
1 1 0 0 0 0 0 0 0 0 0 0 Idle state (flag
clearing required)
1 1 1 0 0 1 0 0 0 0 0 — 1 Start condition
detected
1 — 1 0 0 — 0 0 0 0 — Wait state
1 1 1 0 0 — 0 0 0 0 1 — — Transmission end
(ACKE=1 and
ACKB=1)
1 1 1 0 0 1 0 0 0 0 0 — 1 Transmission end
with ICDRE=0
1 1 1 0 0 — 0 0 0 0 0 — 0 ICDR write with the
above state
1 1 1 0 0 — 0 0 0 0 0 — 1 Transmission end
with ICDRE=1
1 1 1 0 0 — 0 0 0 0 0 — 0 ICDR write with the
above state or after
start condition
detected
1 1 1 0 0 1 0 0 0 0 0 — 1 Automatic data
transfer from
ICDRT to ICDRS
with the above
state
1 0 1 0 0 1 0 0 0 0 — 1 Reception end with
ICDRF=0
1 0 1 0 0 — 0 0 0 0 — 0 ICDR read with the
above state
1 0 1 0 0 — 0 0 0 0 — 1 — Reception end with
ICDRF=1
1 0 1 0 0 — 0 0 0 0 — 0 ICDR read with the
above state
1 0 1 0 0 1 0 0 0 0 — 1 Automatic data
transfer from
ICDRS to ICDRR
with the above
state
0 0 1 0 0 0 1 0 0 — — — Arbitration lost
1 — 0 0 0 — 0 0 0 0 — 0 Stop condition
detected
[Legend]
0: 0-state retained
1: 1-state retained
—: Previous state retained
0
: Cleared to 0
1
: Set to 1
Vista de pagina 327
1 2 ... 323 324 325 326 327 328 329 330 331 332 333 ... 581 582