Renesas TM V.3.20A Especificaciones Pagina 437

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 762
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 436
Renesas Technology, Tools FAQs
Document Number: 01051204_e
Q.
Will the cyclic handler begin processing in the interrupt disable state? Or does it start processing in the interrupt enable state?
A.
The cyclic handler is enabled by an interrupt which has an interrupt level higher than that of the MR30 system clock interrupt.
(Starts at I flag = 1, IPL = system clock Interrupt Priority Level.)
Top of Page | Back to Previous Page
Terms of Use Privacy Policy
(C)2004 Renesas Technology Corp., All Rights Reserved.
Vista de pagina 436
1 2 ... 432 433 434 435 436 437 438 439 440 441 442 ... 761 762

Comentarios a estos manuales

Sin comentarios