Q.
Can I use M3T-PD38SIM to debug an object file generated with IAR's C compiler EW740 (ICC740)?
A.
Yes. Select the EW740 (ICC740) options as specified below, then make an IEEE-695 absolute module file.
In the command line
At Compile "-r" option
At Assemble "-r" option
At Link "-o xxx.695", "-f lnk740.xcl", "-FIEEE695", "-ylmba"
1.
Using Workbench(EW)
From the menu, select [Project] -> [Options...]. This will open the "Options For Target "xxx" Dialog."
Select ICC740 from Category.
Debug tab: Check "Generate debug information".
❍
Select A740 from Category.
Debug tab: Check "Generate debug information".
❍
Select XLINK from Category.
Output tab: Check "Other" in the Format area, select "ieee-695" as the Output format.
Include tab: In the XCL file name area, specify the XCL file to be used (example: lnk740.xcl).
XCL file editing: Add "-ylmba" to the XCL file you are using.
❍
The XCL file name should be specified as the XCL file name you will be using. For more details, refer to the ICC740
Manual.
Please note that source level debug for assembler sources is not supported in versions previous to M3T-PD38SIM V.2.00
Release 1. If you have an older version, please update to the latest M3T-PD38SIM version.
You can download the latest version of M3T-PD38SIM through our Online Upgrade Site.