Q.
Is it possible to use Emulator PC4600 in combination with Emulator Debugger M3T-PD38 and Emulation Pod M38000TL2-FPD?
A.
No it isn't. M3T-PD38 and M38000TL2-FPD are available for use with the PC4701 system. They cannot be used with the PC4600
system.
You must use either WDB38 or RTT74 (an MS-DOS based, discontinued product) as the debugger for the PC4600 system. For an
emulation pod, please use M38000T-POD or M38000TL-POD (both are discontinued products).
The PC4600 system, due to its being a discontinued product, may not be compatible with the MCUs which developed newly. If you
have a new development project using Renesas MCUs, we recommend that you use the PC4701 emulator system.
We have two debugging platforms for our 8-bit MCUs:
PC4701 System
Emulator : PC4701U
Emulation Pod : M38000TL2-FPD
Emulator Debugger : M3T-PD38 (Windows-based application)
Emulator MCU : Available for each MCU
1.
PC4600 System (discontinued product)
Emulator : PC4600 + PC4000E
Emulation Pod : M38000T-POD (bundled with PC4600) or M38000TL-POD
Emulator Debugger : WDB38 or RTT74 (MS-DOS based, discontinued product)
Emulator MCU : Available for each MCU
2.
Note: When using the M38000T-POD emulation pod in combination with the PC4600 system, the pod cannot be used out of the
operation clock frequency and voltage range indicated for PC4600.
Operation clock frequency and voltage range of the PC4600 + M38000T-POD combination is:
Max Operation Clock Frequency : 8MHz
Operation Voltage : 5V±5%
When debugging a target with Vcc > 4.5V, please use the PC4600 + M38000TL-POD combination. The operation clock frequency
and voltage range of the PC4600 + M38000TL-POD combination is:
Max Operation Clock Frequency : 12.5MHz (Vcc = 5.0V with PC4600 high-speed version)
Operation Voltage : 2.5 - 5.5V