Q.
When I start up PD77, I get the following error message. What is causing this error?
"ERROR 11465: Target MCU is unable to reset.\nPlease reset target systems."
A.
The cause of "ERROR 11465" is most likely one of the following:
Faulty contact between emulator and pod or pod and target board.1.
Problems with the reset circuit on the target board (for example, faulty output of reset signal).2.
When this error occurs, down load the firmware after disconnecting the target board from the pod, then confirm proper operations of
PD77.
If PD77 starts up normally, check the reset circuit on the target board.1.
If PD77 does not start up normally, the following two points may be the cause:
Incorrect pod settings
Faulty emulator or pod
2.
Also check for faulty contacts between the emulator, pod, and target board.